Welcome to the Hayward Super Pump 700 manual, your comprehensive guide to installing, operating, and maintaining this high-performance pool pump. This manual ensures safe and efficient use, helping you maximize your pool’s performance while adhering to safety standards and best practices.
Overview of the Hayward Super Pump 700 Series
The Hayward Super Pump 700 Series is a high-performance, self-priming centrifugal pump designed for in-ground swimming pools and spas. Known for its reliability and efficiency, it features a totally enclosed fan-cooled (TEFC) motor for durability and quiet operation. With a chemical-resistant Viton seal, the pump resists corrosion, ensuring long-lasting performance. The series includes models like the SP2670010X15 and SP2670007X10, offering versatile flow rates and head pressures. Its robust design and advanced engineering make it a favorite among pool owners, providing consistent and powerful water circulation for a pristine pool environment. The Super Pump 700 Series is built to deliver exceptional value and reliability season after season.
Important Safety Precautions
Always follow the safety instructions in this manual to prevent severe injury or death. The safety-alert symbol highlights critical precautions. Ensure the strainer cover is securely locked to avoid hazardous situations. Never operate the pump without water, as it can cause damage or overheating. Keep the area around the pump clear of debris and ensure proper ventilation. Adhere to local electrical codes and avoid using damaged power cords. Regular maintenance is essential to prevent malfunctions. Only use genuine Hayward replacement parts to maintain safety and performance. Failure to comply with these precautions may void the warranty or result in operational hazards.
Key Features of the Super Pump 700
The Hayward Super Pump 700 is designed for reliability and efficiency, featuring a high-performance TEFC motor for durability. It includes a chemical-resistant Viton seal, ensuring long-term resistance to corrosion. The pump offers a robust flow rate and head pressure, making it suitable for large in-ground pools. Its self-priming design simplifies startup, while the strainer basket enhances debris collection. The motor is energy-efficient, reducing operational costs. Built with high-quality materials, the Super Pump 700 is designed to withstand harsh pool environments. Its compact design and quiet operation make it a preferred choice for pool owners seeking a reliable and powerful circulation system.
Installation Guidelines
Installation of the Hayward Super Pump 700 requires careful preparation, including pre-installation checks and adherence to manual instructions to ensure safe and efficient operation.
Pre-Installation Checks and Requirements
Before installing the Hayward Super Pump 700, ensure all system components are compatible and meet local regulations. Check the pump’s power requirements and ensure the electrical supply matches the specifications. Inspect the plumbing for proper sizing and connections, and ensure the strainer basket is clean and securely fastened; Verify the pump’s location is level and well-ventilated to prevent overheating. Review the manual for specific guidelines tailored to your model, ensuring compliance with safety standards and manufacturer recommendations. Proper preparation is crucial for efficient operation and longevity of the pump.
Step-by-Step Installation Process
Begin by mounting the Hayward Super Pump 700 on a level, stable surface. Connect the plumbing to the pump’s inlet and outlet ports, ensuring all connections are secure and properly sealed. Next, attach the strainer basket and ensure it is clean and free of debris. Connect the electrical supply, following the wiring diagram in the manual to ensure correct voltage and grounding. Prime the pump by filling the strainer housing with water, then turn on the power to test for leaks and proper operation. Finally, check all connections and settings to ensure optimal performance. Always refer to the manual for specific instructions.
Electrical Connections and Wiring
Before connecting power, ensure the Hayward Super Pump 700 is properly grounded to prevent electrical hazards. Refer to the wiring diagram in the manual for correct terminal connections. Use the appropriate gauge wire to match the pump’s voltage requirements, typically 230V or 115V. Connect the live, neutral, and ground wires securely to the terminal block, double-checking for tight connections. Ensure the circuit breaker or fuse box is rated for the pump’s amperage. Turn on the power briefly to test for proper operation, then shut it off before finalizing any plumbing connections. Always follow local electrical codes and safety guidelines.
Operation and Maintenance
Ensure proper operation by following priming procedures and performing daily checks on strainer baskets and motor function. Regularly inspect and clean the pump to maintain efficiency and longevity.
Starting and Priming the Pump
To start and prime the Hayward Super Pump 700, ensure the strainer housing is filled with water to the suction pipe level. This prevents the pump from running dry and ensures proper priming. Turn off the power supply before priming. Open the strainer cover, fill with water, and securely replace the cover. Restore power and check for leaks. Allow the pump to run for a few minutes to ensure smooth operation. Regularly inspect the strainer basket and clean it if necessary to maintain optimal performance. Always follow the manual’s instructions for priming to avoid damage or inefficient operation.
Daily Operational Checks
Perform daily checks to ensure the Hayward Super Pump 700 operates efficiently. Inspect the strainer basket for debris and clean it regularly to maintain proper water flow. Check the pump housing for any signs of leaks or damage. Ensure the motor is clean and free from obstructions to prevent overheating. Verify that all electrical connections are secure and meet safety standards. Monitor the pump’s performance, listening for unusual noises that may indicate issues. Keep the surrounding area clear to allow adequate airflow. Regularly review the system’s pressure gauge to ensure it operates within the recommended range. These checks help prevent downtime and extend the pump’s lifespan.
Regular Maintenance Tasks
Regular maintenance is crucial for the longevity and efficiency of the Hayward Super Pump 700. Schedule periodic inspections of the motor and pump components to identify wear and tear. Replace the shaft seals every 2-3 years or as needed to prevent leaks. Lubricate moving parts annually to ensure smooth operation. Clean or replace the filter cartridge as recommended to maintain optimal water flow. Check and balance the pool water chemistry to prevent corrosion. Inspect the electrical connections and wiring for damage or degradation. Perform a thorough cleaning of the pump housing and internal components during the off-season. These tasks ensure reliable performance and extend the pump’s service life.
Troubleshooting Common Issues
Identify and resolve common issues with your Hayward Super Pump 700, such as low flow rates, noise, or leaks, by checking for blockages, ensuring proper priming, and verifying electrical connections.
Identifying and Solving Pump Problems
Identify issues with your Hayward Super Pump 700 by checking for common symptoms like low flow rates, unusual noise, or leaks. Start by inspecting the strainer basket for blockages and ensuring it’s clean. Verify proper priming by filling the strainer housing with water. Check electrical connections for damage or loose wires. If the pump doesn’t start, ensure the power supply is correct. For persistent issues, consult the troubleshooting section in the manual for detailed solutions. Always use genuine Hayward replacement parts to maintain performance and warranty validity. Regular maintenance, such as replacing worn seals, can prevent many common problems.
Understanding Error Codes and Solutions
Familiarize yourself with error codes displayed by the Hayward Super Pump 700 to diagnose and resolve issues quickly. Codes like “E1” indicate a power supply problem, while “E2” signals a sensor malfunction. Refer to the manual for a full list of codes and their meanings. For example, “E3” may point to a communication error, requiring a system reset. Always follow the recommended solutions, such as checking connections or replacing faulty sensors. Regular maintenance and using genuine Hayward parts ensure optimal performance and minimize errors. Addressing these issues promptly helps maintain your pool’s efficiency and extends the pump’s lifespan.
Replacement Parts and Accessories
Use only genuine Hayward replacement parts to maintain optimal performance and warranty coverage; Key components include the chemical-resistant Viton seal and durable O-rings. Find parts at authorized Hayward dealers to ensure authenticity and reliability, prolonging your pump’s lifespan and efficiency. Always refer to the manual for a detailed parts list and ordering information.
Locating Genuine Hayward Parts
To ensure optimal performance and maintain your warranty, only use genuine Hayward parts for your Super Pump 700. Visit the official Hayward website or contact authorized dealers to find authentic components. The manual provides a detailed parts list, making it easier to identify what you need. For additional assistance, reach out to Hayward’s customer support or refer to the “Where to Buy” section on their website. Genuine parts are engineered to meet strict quality standards, ensuring longevity and reliability for your pump. Always verify the authenticity of parts to avoid compatibility issues and maintain your pool’s peak performance.
Instructions for Replacing Key Components
When replacing key components of your Hayward Super Pump 700, ensure you use genuine Hayward parts to maintain performance and warranty validity. Start by shutting off the power to the pump and draining the system. Refer to the detailed parts list in the manual to identify the specific component needing replacement. Follow the step-by-step instructions provided for each part, ensuring all connections and seals are secure. If unsure, consult the troubleshooting section or contact Hayward’s customer support. Proper replacement ensures optimal functionality and extends the lifespan of your pump. Always prioritize safety and adhere to the manufacturer’s guidelines for a successful replacement process.
Technical Specifications and Warranty
The Hayward Super Pump 700 offers 1.65 total horsepower with a flow rate of 0-70 GPM. Its dimensions are 22.5 x 12 inches, ensuring compact installation. Covered by a 1-year limited warranty, with a 2-year warranty on the Viton seal, this pump is built to last and perform efficiently under various conditions.
Dimensional and Performance Specifications
The Hayward Super Pump 700 measures 22.5 inches in length and 12 inches in width, making it a compact and space-efficient solution for pool systems. It delivers a maximum flow rate of 70 gallons per minute (GPM) and is powered by a 1.65 total horsepower motor. Designed for reliability, the pump features a durable, chemical-resistant Viton seal to prevent corrosion. Its advanced totally enclosed fan-cooled (TEFC) motor ensures efficient operation and long-term durability. These specifications ensure optimal performance for in-ground pools and spas, providing consistent water circulation and filtration. The pump’s design and engineering make it a trusted choice for pool owners seeking high-quality performance.
Warranty Information and Coverage Details
The Hayward Super Pump 700 is backed by a comprehensive warranty program, ensuring customer satisfaction and product reliability. The pump features a 2-year limited warranty on the Viton seal, while other components are covered for 1 year from the date of installation. This warranty applies to defects in materials and workmanship under normal use and conditions. Improper installation, misuse, or the use of non-genuine Hayward replacement parts may void the warranty. For detailed terms and conditions, refer to the official Hayward warranty statement. Hayward also provides dedicated customer support to address any warranty-related inquiries or claims, ensuring a hassle-free experience for pool owners.